Search results for "teva resin"

  • Tagami, K.; Uchida, S.

    Use of TEVA resin for the determination of U isotopes in water samples by Q-ICP-MS, Applied Radiation and Isotopes, Vol. 61 (2/3), pp. 255-259, (2004)

    Actinides in Water using TEVA Resin and ICP-MS (TK104 )

  • Porter, C.E.; et al

    Fermium Purification Using TEVA Resin Extraction Chromatography, Separation Science & Technology, Vol. 32, No.1-4, pp. 83-92, (1997)

    Fm, Cm, Y, Dy, Ho, Cf, Es, Bk in Aqueous using TEVA Resin (PO197 )

  • Pilvio, Riita; Bickel, M.

    Separation of U, Th, Pu, Am qnd Cm with TRU and UTEVA Resins, Eichrom Users’ Group Meeting, Karlsruhe, Germany, (1998)

    U, Th, Pu, Am, Cm in Environmental using UTEVA Resin, TRU Resin and alpha-spec (PI297 )

  • Tagami, K.; Uchida, S.

    Comparison of the TEVA-Spec resin and liquid-liquid extraction methods for the separation of technetium in soil samples, Journal of Radioanalytical & Nuclear Chemistry, Vol. 239, No. 3, pp. 643-648, (1999)

    Tc in Soil using and (TK198 )

    [ doi: 10.1007/BF02349084 ]

  • Yokoyama, T.; et al

    Separation of Thorium and Uranium from Silicate Rock Samples Using Two Commercial Extraction Chromatographic Resins, Anal. Chem., Vol. 71, pp. 135-141, (1999)

    Th, U in Silicate Rocks, Soil using UTEVA Resin, TEVA Resin and TIMS (YT199 )

    [ doi: 10.1021/ac9805807 ]

  • Tagami, K.; Uchida, S.

    Separation of rhenium by an extraction chromatographic resin for determination by inductively coupled plasma-mass spectrometry, Analytica Chimica Acta, (1999)

    Tc, Re in General using TEVA Resin and ICP-MS (TK100 )

  • Sullivan T.; et al

    Determination of Technetium-99 in Borehole Waters Using an Extraction Chromatographic Resin (1), 37th Annual Conference On Bioassay, Analytical And Environmental Radiochemistry. Ottawa, Canada, (1991)

    Tc in Borehole Waters using TEVA Resin and LSC (ST191 )

  • Qu, H.; et al

    Preconcentration of Plutonium and Americium Using the Actinide-CU Resin for Human Tissue Analysis, Journal of Radioanalytical & Nuclear Chemistry, Vol. 234, No. 1-2, pp. 175-181, (1998)

    Pu, Am in Human Tissue using TRU Resin, TEVA Resin, UTEVA Resin and LSC, alpha-spec (QH198 )

    [ doi: 10.1007/BF02389768 ]

  • Henderson, B.

    Determination of Selective Actinides in Water and Air Filters (Eichrom Resin Column Method with Alpha Spec), Eichrom Atlanta Users Seminar, Atlanta, GA, (1996)

    U, Pu, Am in Water, Air Filter using UTEVA Resin, TRU Resin and alpha-spec (HB196 )

  • Dietz, M.L.; et al

    An Improved Extraction Chromatographic Resin for the Separation of Uranium from Acidic Nitrate Media, Atlanta, Vol. 54, pp. 1173-1184, (2001)

    U in Urine using UTEVA-2 Resin (DM101 )

    [ doi: 10.1016/S0039-9140(01)00390-3  ]

  • Dulaiova, Henrieta

    Separation of Am and Pu from 50g Soil and Sediment Samples (Diphonix-HEDPA-TRU-TEVA), (2001)

    Actinides in Large Soil using Diphonix Resin, TEVA Resin, UTEVA Resin, TRU Resin and alpha-spec (DH101 )

    Download
  • Corbett, D.R.; Schultz, M.; Burnett, W.

    Actinide Separations from Soils and Sediment with ACU Resin, Eichrom Atlanta Users’ Seminar, Atlanta, GA, (1996)

    Actinides in Soil, Sediment using Actinide Resin, UTEVA Resin, TRU Resin and alpha-spec (CO196 )

  • Berne, Anna

    TRU-Spec and TEVA-Spec Used to Separate Th and Nd from Am after Microprecipitation, 40th Annual Conference On Bioassay, Analytical and Environmental Radiochemistry. Cincinnati, Ohio. November (Eichrom Workshop)., (1994)

    Nd, Th, Am in Soil using TRU Resin, TEVA Resin and alpha-spec (BE194 )

  • Horwitz, E.P.

    New Chromatographic Materials for Determinations of Actinides, Strontium, and Technetium in Environmental, Bioassay, and Nuclear Waste Samples, New Chromatographic Materials for Determinations of Actinides, Strontium, and Technetium in Environmental, Bioassay, and Nuclear Waste Samples, (E), (1993)

    Am, Pu, U, Th, Np, Sr, Tc in using Sr Resin, TRU Resin, UTEVA Resin, TEVA Resin and (ZZ931 )

    Download
  • Uchida, S.; et al

    Rapid Separation Method of Technetium-99 in Water Samples by ICP-MS (Article in Japanese), Health Physics (Japan), Vol. 33, No. 1, pp. 35-39, (1998)

    Tc in Water using TEVA Resin and ICP-MS (US198 )

  • Uchida, S.; et al

    Rapid Separation Method of Technetium-99 in Water Samples by ICP-MS (Article in English), Radioactivity & Radiochemistry, Vol. 10, No. 2, pp. 23-29, (1999)

    Tc in Water using TEVA Resin and ICP-MS (US198E )

  • United States Environmental Protection Agency

    Rapid Radiochemical Methods for Selected Radionuclides in Water for Environmental Restoration Following Homeland Security Events, EPA 402-R-10-001, EPA 402-R-10-001, (2010)

    U, Pu, Am, Sr, Ra in Water, Emergency Response Methods using TRU Resin, UTEVA Resin, Diphonix Resin, MnO2 Resin, Sr Resin and alpha-spec, gas flow proportional (US110 )

    Download
  • Uchida, S.; Tagami, K.; Tabei, K.

    Comparison of alkaline fusion and acid digestion methods for the determination of rhenium in rock and soil samples by ICP-MS, Analytica Chimica Acta, Vol. 535, pp. 317-323, (2005)

    Re in Rock, Soil using TEVA Resin and ICP-MS (US105 )

  • Tagami, K.; Uchida, S.

    Determination of rhenium in manganese nodules by inductively coupled plasma mass spectrometry, Journal of Radioanalytical and Nuclear Chemistry, Vol. 273, No. 1, pp. 147-150, (2007)

    Re, Tc in Seawater using TEVA Resin and ICP-MS (TK207 )

  • Tagami, K.; Uchida, S.

    Use of a Combustion Apparatus for Low-Level 99TC Separations from Soil Samples, Radioactivity & Radiochemistry, Vol. 10, No. 2, pp. 30-34, (1999)

    Tc in Soil using TEVA Resin and ICP-MS (TK199 )

  • Tagami, K.; Uchida, S.

    A Simple ICP-MS Method for the Determination of Rhenium in Seawater and Its Concentration in Tokyo Bay, Atomic Spectroscopy, Vol. 24 (6), pp 201-205, (2003)

    Re in Seawater using TEVA Resin and ICP-MS (TK103 )

  • Tagami, K.; Uchida, S.

    ICP-MS Determination of Re at Ultra Trace Levels in Rock and Soil Samples, Journal of Analytical Atomic Spectrometry, Vol. 16, pp. 669-671, (2001)

    Re in Rock, Soil using TEVA Resin and ICP-MS (TK101 )

    [ doi: 10.1039/b101855h ]

  • Thakkar, A.H.

    Rapid Sequential Separation of Actinides Using Eichrom’s Extraction Chromatographic Material, Journal of Radioanalytical & Nuclear Chemistry, Vol. 248, No. 2, pp. 453-456, (2001)

    Actinides in Bioassay using UTEVA Resin, TRU Resin and alpha-spec (TA101 )

    [ doi: 10.1023/A:1010660915984 ]

  • Thakkar, A.H.

    Rapid Sequential Separation of Actinides Using Eichrom’s Extraction Chromatographic Material, Journal of Radioanalytical & Nuclear Chemistry, Vol. 252, No. 2, pp. 215-218, (2002)

    Actinides in Bioassay using UTEVA Resin, TRU Resin and alpha-spec (TA102 )

    [ doi: 10.1023/A:1015737516054 ]

  • Seki, T.; Oguma, K.

    Determination of Thorium in High Purity Aluminum by ICP-Mass Spectrometry after Matrix Removal by On-line Solid Phase Extraction, Journal of Flow Injection Analysis, Vol. 18, No. 2, pp. 140-143, (2001)

    Th in Aluminum using TEVA Resin and ICP-MS (ST011 )

  • Scarpitta, S C.

    Technetium-99 in Water and Vegetation by Liquid Scintillation Analysis, 39th Annual Conference on Bioassay, Analytical and Environmental Radiochemistry., Colorado Springs, CO+H217, (1993)

    Tc in Water, Vegetation using TEVA Resin and LSC (SS193 )

  • Smith, L.L.; et al

    Improved Separation Method for Determining Actinides in Soil Samples, Journal Of Radioanalytical & Nuclear Chemistry, Articles, Third International Conference On Methods & Applications Of Radioanalytical Chemistry. 194, 1 151-156., (1995)

    Actinides in Soil using Diphonix Resin, TRU Resin, TEVA Resin and alpha-spec, ICP-MS (SL195 )

    [ doi: 10.1007/BF02037621 ]

  • Saito, Takashi; et al

    U-234/U-238 Activity Ratios of Uranium in Bauxite and Aluminum Compounds, Radioisotopes, Vol. 46, No. 6, pp. 331-335, (1997)

    U in Bauxite, Aluminium Compounds using UTEVA Resin and alpha-spec (SN197 )

  • Technetium-99 Analysis Using Extraction Chromatography, DOE Methods Compendium RP550, (1993)

    Tc in Aqueous using TEVA Resin and LSC (RP550 )

  • Pappas, R.S.; et al

    Rapid Analysis for Plutonium-239 in 1 ml of Urine by Magnetic Sector Inductively Coupled Plasma Mass Spectrometry with a Desolvating Indroduction System, J. Anal. At. Spectrom, Vol. 19, pp. 762-766, (2004)

    Pu in Urine using TEVA Resin and ICP-MS (PR104 )

    [ doi: 10.1039/b316851d ]

  • Pimpl, M.; Higgy, R.H.

    Improvement of Am and Cm Determination in Soil Samples, Journal of Radioanalytical & Nuclear Chemistry, Vol. 248, No. 3, pp. 537-541, (2001)

    Pu, Am, Cm in Soil using TEVA Resin, TRU Resin and alpha-spec (PM101 )

    [ doi: 10.1023/A:1010658310049 ]

  • Paulus, M.

    Applications Support Specialist, Gilson Technical Communiqué No. 2, (1996)

    U in Water, Soil, Sludge, Microwaved Samples using UTEVA Resin and alpha-spec (PM196 )

  • Pilvio, Riita; Bickel, M.

    Separation of Actinides Using Extraction Chromatography, International Workshop on the Status of Measurement Techniques for the Identification of Nuclear Signatures, Geel, Belgium, (1997)

    U, Th, Pu, Am, Cm in Environmental using UTEVA Resin, TRU Resin and alpha-spec (PI197 )

  • Oguma, K.; et al

    Determination of Traces of Metals in Steel by Ion-exchange Separation and Atomic Spectrometry, Iron & Steel, Vol. 85, No. 2, pp. 119-123 (Japanese Language), (1999)

    Trace Metals in Steel using TEVA Resin and AA (OK991 )

  • Nour, S.; Burnett, W.; Horwitz, E.P.

    234Th Analysis of Marine Sediments via Extraction Chromatography and Liquid Scintillation Counting, Applied Radiation and Isotopes, Vol. 57, pp. 235-241, (2002)

    Th in Sediment using TEVA Resin and LSC (NS102 )

    [ doi: 10.1016/S0969-8043(02)00088-X  ]

  • Nguyen, S.; et al

    Simple Separation Procedure for Actinides in Bioassay Samples Using Eichrom Column, 39th Annual Conference On Bioassay, Analytical And Environmental Radiochemistry. Colorado Springs, CO, (1993)

    Actinides in Bioassay using UTEVA Resin, TRU Resin and alpha-spec (NS193 )

  • Maxwell, S.L.; Culligan, B.K.; J.B. Hutchison

    Rapid fusion method for determination of plutonium isotopes in large rice samples, Journal of Radioanalytical and Nuclear Chemistry, Online 06 May 2013, (2013)

    Pu in Food, Rice using TEVA Resin and alpha-spec, ICP-MS, SF-ICP-MS (MS113 )

    [ doi: 10.1007/s10967-013-2515-x ]

  • Maxwell, S.L.; Culligan, B.K.; Noyes, G.W.

    Rapid separation method for 237Np and Pu isotopes in large soil samples, Applied Radiation and Isotopes, Vol. 69, Issue 7, pp 917-923, (2011)

    Np, Pu in Soil using TEVA Resin and alpha-spec (MS211 )

    [ doi: 10.1016/j.apradiso.2011.01.021 ]

  • Maxwell, S.L.; Culligan, B.K.; Kelsey-Wall, A.; Shaw, P.J.

    Rapid radiochemical method for determination of actinides in emergency concrete and brick samples, Analytica Chimica Acta, Vol. 701, Issue 1, pp 112-118, (2011)

    Actinides, Pu, Np, Am, Cm, U in Concrete, Brick, Emergency Response Methods using TEVA Resin, DGA Resin, TRU Resin and alpha-spec (MS111 )

    [ doi: 10.1016/j.aca.2011.06.011 ]

  • Maxwell, S.L.; Culligan, B.K.; Kelsey-Wall, A.; Shaw, P.J.

    Rapid determination of actinides in emergency food samples, Journal of Radioanalytical and Nuclear Chemistry, Volume 292, Number 1, 339-347, (2012)

    Actinides, Pu, Np, Am, Cm, U in Food, Emergency Response Methods using TEVA Resin, DGA Resin, TRU Resin and alpha-spec (MS112 )

    [ doi: 10.1007/s10967-011-1411-5 ]

  • Maxwell, S.L.; Culligan, B.K.; Jones, V.D.; Nichols, S.T.; Bernard, M.A.; Noyes, G.W.

    Determination of 237Np and Pu isotopes in large soil samples by inductively coupled plasma mass spectrometry, Analytica Chimica Acta, Vol. 682, Issues 1-2, pp 130-136, (2010)

    Np, Pu in Soil using TEVA Resin, DGA Resin and ICP-MS, alpha-spec (MS410 )

    [ doi: 10.1016/j.aca.2010.10.001 ]

  • Maxwell, S.L.; Culligan, B.K.; Noyes, G.W.

    Rapid separation method for actinides in emergency soil samples, Radiochimica Acta, Vol. 98, No. 12, pp. 793-800., (2010)

    Actinides, Cm, Am, Pu, U in Soil, Emergency Response Methods using UTEVA Resin, TRU Resin, DGA Resin and alpha-spec (MS510 )

    [ doi: 10.1524/ract.2010.1785 ]

  • Maxwell, S.L.; Culligan, B.K.; Noyes, G.W.

    Rapid separation of actinides and radiostrontium in vegetation samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 286, No.1, pp 273-282, (2010)

    Actinides, Sr, U, Pu, Am, Cm, Np, Th in Vegetation, Emergency Response Methods using TEVA Resin, TRU Resin, Sr Resin and alpha-spec, GPC (MS210 )

    [ doi: 10.1007/s10967-010-0653-y ]

  • Maxwell, S.L.; Culligan, B.K.; Noyes, G.W.

    Rapid separation method for actinides in emergency air filter samples, Applied Radiation and Isotopes, Vol. 68, No. 12, pp 2125-2131, (2010)

    Actinides, Sr, U, Pu, Am, Cm, Np, Th in Air Filter using TEVA Resin, TRU Resin, Sr Resin and alpha-spec, GPC (MS110 )

    [ doi: 10.1016/j.apradiso.2010.05.018 ]

  • Maxwell, S.L.; Culligan, B.K.; Jones, V.D.; Nichols, S.T.; Noyes, G.W.

    Rapid determination of 237Np and Pu isotopes in water by inductively-coupled plasma mass spectrometry and alpha spectrometry, Journal of Radioanalytical and Nuclear Chemistry, Vol. 287, No. 1, pp 223-230, (2010)

    Np, Pu in Water using TEVA Resin, DGA Resin and ICP-MS (MS310 )

    [ doi: 10.1007/s10967-010-0825-9 ]

  • Maxwell, S.L.; Jones, V.D.

    Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: A hybrid approach, Talanta, Vol. 80, No. 1, pp 143-150, (2009)

    Actinides, Pu, Np, Am, U, Cm in Urine using TEVA Resin, DGA Resin, TRU Resin and ICP-MS, alpha-spec (MS309 )

    [ doi: 10.1016/j.talanta.2009.06.041 ]

  • Maxwell, S.L.; Culligan, B.K.

    New column separation method for emergency urine samples, Journal of Radioanalytical and Nuclear Chemistry , Vol. 279, No. 1, pp 105-111, (2009)

    Am, Pu, U, Sr in Urine using TEVA Resin, TRU Resin, Sr Resin and alpha-spec, GPC (MS409 )

    [ doi: 10.1007/s10967-007-7209-9 ]

  • Maxwell, S.L.; et al

    New method for removal of spectral interferences for beryllium assay using inductively coupled plasma atomic emission spectrometry, Talanta, Vol. 76, pp. 432-440, (2008)

    Be in Swipes, Filter, Air Filter using Diphonix Resin, TEVA Resin, Anion Exchange Resin and ICP-AES (MS108 )

    [ doi: 10.1016/j.talanta.2008.03.032 ]

  • Maxwell, S.L.; Culligan, B.K.

    Rapid Separation Method for Emergency Water and Urine Samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 279. No 3, pp 901-907, (2009)

    Am, Pu, U, Sr in Water, Urine using TEVA Resin, TRU Resin, Sr Resin and alpha-spec, GPC (MS209 )

    [ doi: 10.1007/s10967-008-7387-0 ]

  • Maxwell, S.L.; Faison, D.M.; Hutchison, J.B.

    New Method for Determination of Actinides and Strontium in Animal Tissue, Journal of Radioanalytical and Nuclear Chemistry, Vol. 275, No. 3, (2007)

    Pu, Np, U, Am, Cm, Sr in Fish Tissue, Marine, Animal Tissue using TEVA Resin, TRU Resin, DGA Resin, Sr Resin and alpha-spec, GPC (MS307 )

    [ doi: 10.1007/s10967-007-7120-4 ]

  • Maxwell, S.L.; Faison, D.M.

    Rapid column extraction method for actinides and strontium in fish and other animal tissue samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 275, No. 3, pp 605-612, (2007)

    Actinides, Pu, Np, U, Am, Cm, Sr in Animal Tissue, Fish, Deer, Beef, Shellfish, Hogs, Pigs using TEVA Resin, TRU Resin, DGA Resin, Sr Resin and alpha-spec, GPC (MS407 )

    [ doi: 10.1007/s10967-007-7120-4 ]

  • Maxwell, S.L.

    Rapid Method for Determination of Plutonium, Americium and Curium in Large Soil Samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 275, No. 2, (2007)

    Cm, Pu, Am in Soil using TEVA Resin, DGA Resin, TRU Resin and alpha-spec (MS107 )

    [ doi: 10.1007/s10967-007-7032-3 ]

  • Maxwell, S.L.

    Rapid Analysis of Emergency Urine and Water Samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 275, No. 3, (2007)

    Sr, Pu, Np, U, Am, Cm, Th in Water, Urine using TEVA Resin, TRU Resin, Sr Resin and alpha-spec, GPC (MS207 )

    [ doi: 10.1007/s10967-007-7084-4 ]

    Download
  • Maxwell, S.L.

    Rapid Column Extraction Method for Actinides and Sr-89,90 in Water Samples, Journal of Radioanalytical and Nuclear Chemistry, Vol. 267, No. 3, pp. 537-543, (2006)

    U, Pu, Am, Th, Cm, Np, Sr in Water using TEVA Resin, TRU Resin, Sr Resin, DGA Resin and alpha-spec, GPC (MS106 )

    [ doi: 10.1007/s10967-006-0083-z ]

  • Maxwell, S.L.; Culligan, B.K.

    Rapid Column Extraction Method for Actinides in Soil, Journal of Radioanalytical and Nuclear Chemistry, Vol. 270, No. 3, pp. 699-704, (2006)

    Actinides, Pu, Am, U, Np, Cm in Soil using TEVA Resin, TRU Resin, DGA Resin and alpha-spec (MS306 )

    [ doi: 10.1007/s10967-006-0449-2 ]

  • Maxwell, S.L.; Nichols, S.T.

    Actinide Recovery Method for Large Soil Samples, Radioactivity & Radiochemistry, Vol. 11, No. 4, pp. 46-54 (MS200), (2000)

    Actinides in Soil using Diphonix Resin, TEVA Resin, UTEVA Resin, TRU Resin and alpha-spec (MS200 )

  • Maxwell, S.L.; Fauth, D.J.; Nichols, S.T.

    New Fecal Method for Plutonium and Americium, Journal of Radioanalytical & Nuclear Chemistry, Vol. 250, No. 1, pp. 117-121, (2001)

    Am, Pu in Bioassay using Diphonix Resin, TEVA Resin, TRU Resin and alpha-spec (MS101 )

    [ doi: 10.1023/A:1013280601044 ]

  • Maxwell, S.L.; Satkowski, J.

    Rapid Mass-Spectrometry Method for Uranium and Plutonium, Radioactivity & Radiochemistry, Vol. 12, No. 2, pp. 12-20, (2001)

    U, Pu in Mixed U/Pu Oxides using TEVA Resin, UTEVA Resin and TIMS (MS201 )

  • Maxwell, S.L.; Fauth, D.J.

    Rapid Column Extraction Methods for Urine, Radioactivity & Radiochemistry, Vol. 11, No. 3 , (2000)

    Actinides in Urine using TEVA Resin, TRU Resin, Sr Resin and alpha-spec (MS100 )

    Download
  • Maxwell, S.L.; Nelson, M.

    Measurement of Actinides and Strontium-90 in High Activity Waste (U), Inst. Of Nuclear Materials Management 35th Annual Meeting. Naples, FL (WSRC-MS-94-0163)., (1994)

    Actinides in High Activity Waste using Sr Resin, TEVA Resin, UTEVA Resin, TRU Resin and LSC (MS194 )

  • Maxwell, S.L.

    Rapid Actinide-Separation Methods, Radioactivity & Radiochemistry, Vol. 8, No. 4, pp. 36-44, (1998)

    Actinides in Nuclear Waste, Environmental using TEVA Resin, UTEVA Resin, TRU Resin and alpha-spec, ICP-MS (MS198 )

    Download
  • Maxwell, S.L.; et al

    High-Speed Separations to Measure Impurities in Pu-238 Oxide and Trace Radionuclides in High-Activity Waste, 34th ORNL/DOE Conference On Analytical Chemistry In Energy Technology, Gatlinburg, TN, (1993)

    Pu, U, Np, Th in High Activity Waste using TEVA Resin, UTEVA Resin and alpha-spec (MS193 )

  • Moir, D.L.; Joseph, D.L.

    Determination of Tc-99 in Fuel Leachates Using Extraction Chromatography, Journal of Radioanalytical & Nuclear Chemistry, Vol. 220, No. 2 , pp. 195-199, (1997)

    Tc in Fuel Leachates using TEVA Resin and LSC (ML197 )

    [ doi: 10.1007/BF02034855 ]

  • Mas, J.L.; et al

    Method for the Detection of Tc in Seaweed Samples Coupling the use of Re as a Chemical Tracer and Isotope Dilution Inductively Coupled Plasma Mass Spectrometry, Analytica Chimica Acta, Vol. 509, pp. 83-88, (2004)

    Tc in Seaweed using TEVA Resin and ICP-MS (MJL104 )

    [ doi: 10.1016/j.aca.2003.12.014  ]

  • Mas, J.L.; et al

    Rhenium measurements on North Atlantic seaweed samples by ID-ICP-MS: an observation on the Re concentration factors, Journal of Radioanalytical and Nuclear Chemistry, Vol. 265(3), pp. 361-365, (2005)

    Re, Tc in Seaweed using TEVA Resin and ICP-MS (MJL105 )

  • McAlister, D.R.; Horwitz, E. P.

    Chromatographic generator systems for the actinides and natural decay series elements, Radiochimica Acta, Vol. 99, No. 3, pp. 151-159, (2011)

    Bi, Po, Pb, Ra, Ac, Th, Np in Medical Isotope Production using TEVA Resin, DGA Resin, UTEVA Resin, Sr Resin, Pre-Filter Resin, C8 Resin and alpha-spec, GPC, gamma-spec, LSC (MD111 )

    [ doi: 10.1524/ract.2011.1804 ]

  • Mann, D.K.; Spence, V.; Berrier, P.

    Determination of Tc-99 in K-25 Site Cooling Tower Wood Leachates, 39th Annual Conference. on Bioassay Analytical and Environmental Radiochemistry (Eichrom Workshop), Colorado Springs, CO, (1993)

    Tc in Cooling Tower Wood Leachates using TEVA Resin and LSC (MA193 )

  • Mann, D.K.; et al

    Automation; The Next Step?, Eichrom Cincinnati Users’ Seminar. Cincinnati, OH, (1996)

    U in Water using UTEVA Resin and SPE (MA196 )

  • Li, T.K.; et al

    Simultaneous measurements of plutonium and uranium in spent-fuel dissolver solutions, 38. annual meeting of the Institute of Nuclear Materials management, Phoenix, AZ Jul 20-24, 1997, (1997)

    Pu, U in Spent Nuclear Fuel using UTEVA Resin and gamma-spec (LT197 )

  • Langston, R.; Nguyen, S.; Simpson, T.

    A Procedure for the Determination of Neptunium, Uranium and Thorium in Urine, 41st Annual Conference on Bioassay, Analytical and Environmental Radiochemistry, Boston, MA, (1995)

    Np, U, Th in Urine using UTEVA Resin, TRU Resin and alpha-spec (LR195 )

  • Laue, C.A.; Sudowe, R.; Gregorich, K.E.; Hoffman, D.C.

    Development of a Fast and Efficient Separation for Short-Lived Plutonium Isotopes Produced in Accelerator-Based Irradiations, Solvent Extraction & Ion Exchange, Vol. 18, No. 2, pp. 203-222 , (2000)

    Pu in Aerosol using TEVA Resin and alpha-spec (LC100 )

  • Kenna, T.C.

    Determination of Plutonium Isotopes and Neptunium-237 in Environmental Samples by Inductively Coupled Plasma Mass Spectrometry with Total Sample Dissolution, J. Anal. At. Spectrom, Vol. 17, pp. 1471-1479, (2002)

    Pu, Np in Total Digested Sediment using TEVA Resin and ICP-MS (KT102 )

    [ doi: 10.1039/b205001c ]

  • Ketterer, M.E.; Hafer, K.M.; Jones, V.J.; Appleby, P.G.

    Rapid dating of recent sediments in Loch Ness: inductively coupled plasma mass spetrometric measurements of global fallout plutonium, Science of the Total Environment, Vol. 322, pp. 221-229, (2004)

    Pu in Sediment using TEVA Resin and ICP-MS (KM203 )

    [ doi: 10.1016/j.scitotenv.2003.09.016  ]

  • Ketterer, M.E.; Hafer, K.M.; Mietelski, J.W.

    Resolving Chernobyl vs. global fallout contributions in soils from Poland using Plutonium atom ratios measured by inductively coupled plasma mass spectrometry, Journal of Environmental Radioactivity, Vol. 73, pp. 183-201, (2004)

    Pu in Soil using TEVA Resin and ICP-MS (KM303 )

    [ doi: 10.1016/j.jenvrad.2003.09.001   ]

  • Ketterer, M.E.; Szechenyi, S.C.

    Determination of plutonium and other transuranic elements by inductively coupled plasma mass spectrometry : A historical perspective and new frontiers in the environmental sciences, Spectrochimica acta. Part B : Atomic spectroscopy, vol. 63, no7, pp. 719-737, (2008)

    Pu, Np, Am in Environmental, Geological using TEVA Resin, TRU Resin, UTEVA Resin and ICP-MS, MC-ICP-MS, SF-ICP-MS (KM108 )

    [ doi: 10.1016/j.sab.2008.04.018 ]

  • Ketterer, M.E.; Jordan, J.A.; Szechenyi, S.C.; Hudson, D.D.; Layman, R.R.

    Envirogeochemical exploration for “NORM” wastes: quadrupole enductively coupled plasma mass spectrometric measurements of thorium and uranium isotopes, Journal of Analytical Atomic Spectrometry, Vol. 15, pp. 1569-1573, (2000)

    Th, U in Soil, Environmental using TRU Resin, UTEVA Resin and ICP-MS (KM200 )

    [ doi: 10.1039/b001787f ]

  • Ketterer, M.E.; Hafer, K.M.; Link, C.L.; Royden, C.S.; Hartsock, W. J.

    Anthropogenic U-236 at Rocky Flats, Ashtabula river harbor, and Mersey estuary: three case studies by sector inductively coupled plasma mass spectrometry, Journal of Environmental Radioactivity, Vol. 67, pp. 191-206, (2003)

    U in Soil, Sediment using UTEVA Resin and ICP-MS (KM103 )

    [ doi: 10.1016/S0265-931X(02)00186-8  ]

  • Ketterer, M.E.; Hafer, K.M.; Link, C.L.; Kolwaite, D.; Wilson, J.; Mietelski, J.W.

    Resolving global versus local/regional Pu sources in the environment using sector ICP-MS, Journal of Analytical Atomic Spectrometry, Vol. 19, pp. 241-245, (2004)

    Pu in Soil using TEVA Resin and ICP-MS (KM104 )

    [ doi: 10.1039/b302903d ]

  • Ketterer, M.E.; Wetzel, W.C.; Layman, R.R.; Matisoff, G.; Bonniwell, E.C.

    Isotopic Studies of Sources of Uranium in Sediments of the Ashtabula River, Ohio, USA, Environmental Science & Technology , Vol. 34, pp. 966-972, (2000)

    U, Trace Metals in Sediment using UTEVA Resin and gamma-spec, ICP-MS (KM100 )

    [ doi: 10.1021/es981314d ]

  • Kim, Cheol-Su; et al

    Rapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry, Department of Environmental Radioactivity Assessment, Korea Institute of Nuclear Safety, Yusong, Taejon; Department of Nuclear Engineering, Korea Advanced Institute of Science and Technology, Korea,  305-338, (2000)

    Pu in Environmental using TEVA Resin, Sr Resin and ICP-MS (KC100 )

  • Kim, Guebuem; Burnett, W.; Horwitz, E.P.

    Efficient Preconcentration and Separation of Actinide Elements from Large Soil and Sediment Samples, Analytical Chemistry, Vol. 72, pp. 4882-4887, (2000)

    Actinides in Large Soil using Diphonix Resin, TEVA Resin, UTEVA Resin, TRU Resin and alpha-spec (KG200 )

    [ doi: 10.1021/ac000417n ]

    Download
  • Jassin, L.E.

    Radiochemical Separation Advancements Using Extraction Chromatography: A Review of Recent Eichrom Users’ Group Workshop Presentations with a Focus on Matrix Interferences, Journal of Radioanalytical and Nuclear Chemistry, Vol. 263, No. 1, pp. 93-96, (2005)

    Various in Various using TEVA Resin, Uteva Resin, TRU Resin, Sr Resin and Various (JL105 )

    [ doi: 10.1007/s10967-005-0018-0 ]

  • Horwitz, E.P.; Chiarizia, R.; Gatrone, R.C.

    Am(III) and Eu(III) Extraction by Aliquat·336 and Benzyl Substituted Quaternary Ammonium Sales from Nitrate and Thiocyanate Solutions, Solvent Extraction & Ion Exchange, Vol. 13, No. 4, pp. 615-645 (HP295), (1995)

    Am, lanthanides in Water using TEVA Resin and alpha-spec (HP395 )

  • Horwitz, E.P.; et al

    Decontamination of Waste Solution from Davies-Gray Analyses in a Pilot-Facility for Process Development, Separation Science & Technology, Vol. 30, pp. 1373-1354, (1995)

    Actinides in Davies-Gray Waste using Diphonix Resin, UTEVA Resin and ICP-AES, ICP-MS (HP295 )

  • Horwitz, E.P.; et al

    Separation and Preconcentration of Uranium from Acidic Media by Extraction Chromatography, Analytica Chimica Acta, Vol.266, pp. 25-37, (1992)

    U in Acidic Media using UTEVA Resin and (HP392 )

    [ doi: 10.1016/0003-2670(92)85276-C   ]

    Download
  • Horwitz, E.P.

    Extraction Chromatography of Actinides and Selected Fission Products: Principles and Achievement of Selectivity, presented at International Workshop on the Application of Extraction Chromatography in Radionuclide Measurement, IRMM, Geel 9-10, Belgium, (1998)

    Actinides, Sr in Mixed Samples using TEVA Resin, UTEVA Resin, TRU Resin, Actinide Resin, Sr Resin and (HP199 )

    Download
  • Horwitz, E.P.; Dietz, M.; Chiarizia, R.; Diamond, H.; Maxwell, S.L.; Nelson, M.

    Separation and Preconcentration of Actinides by Extraction Chromatography Using a Supported Liquid Anion Exchanger: Application to the Characterization of High-Level Nuclear Waste Solutions, Analytica Chimica Acta, Vol. 310, pp. 63-78, (1995)

    Actinides in High Level using TEVA Resin and alpha-spec, GPC (HP195 )

    [ doi: 10.1016/0003-2670(95)00144-O  ]

    Download
  • Hill, P.

    Streamlining a Production Radiochemistry Laboratory Using Eichrom Extraction Chromatography, Eichrom Southeast Users’ Workshop, Augusta, GA, (1994)

    Th, Pu, Am, Cm, U in Environmental using TEVA Resin, UTEVA Resin and alpha-spec (HI194 )

  • Huff, E.A.

    Partition Chromatographic Studies of Americium, Yttrium and the Rare Earths in the Tricaprylylmethylammonium Thiocyanate-Ammonium Thiocyanate System, Journal of Chromatography, Vol. 27, pp. 229-236, (1967)

    Am, Rare Earths in Soil using TEVA Resin (HE167 )

    [ doi: 10.1016/S0021-9673(01)85854-4   ]

  • Ham, G. 

    Determination of Actinides in Environmental Materials Using Extraction Chromatography, 7th International Symposium On Radiochemical Analysis.  Bournemouth, UK, (1994)

    Am in Environmental using TRU Resin, TEVA Resin and alpha-spec (HG194 )

  • Gingell, T.

    The Determination of Uranium in Environmental Samples Using Extraction Chromatography, Journal of Radioanalytical & Nuclear Chemistry, Vol. 226, Nos. 1-2, pp. 185-189, (1997)

    U in Environmental using UTEVA Resin and alpha-spec (GT197 )

    [ doi: 10.1007/BF02063644 ]

  • Goodall, P.; Lythgoe, C.

    Rapid Separation of Uranium and Plutonium by Extraction Chromatography for Determination by Thermal Ionisation Mass Spectrometry, The Analyst, Vol. 124, pp. 263-269, (1999)

    U, Pu in Spent Nuclear Fuel using UTEVA Resin and TIMS (GP199 )

    [ doi: 10.1039/a809219b ]

  • Goldstein, S.J.; et al

    Measurement and Application of Uranium Isotopes for Human and Environmental Monitoring, Health Physics , Vol. 72, No. 1, pp. 10-18, (1997)

    U in Bioassay, Environmental using UTEVA Resin and alpha-spec (GS197 )

  • Godoy, M.L.; et al

    234U and 230Th determination by FIA-ICP-MS and application to uranium-series disequilibrium in marine samples, Journal of Environmental Radioactivity, Article in Press, pp. 1-9, (2006)

    U, Th in Soil, Sediment using UTEVA Resin and ICP-MS (GM106 )

    [ doi: 10.1016/j.jenvrad.2005.12.012   ]

  • Gilson, Inc. (Marisue Paulus)

    Radiochemistry Application of Gilson ASPEC XLi, Technical Communique No. 2. Radiochemistry Application on ASPEC Xli.

    U in Water, Soil, Sludge, Microwaved Samples using UTEVA Resin and alpha-spec (G197 )

  • Good, C.; Shultz, A.

    New Methods for the Determination of Transuranics, Boron, and Silicon in Uranium Hexafluoride, Lockheed Martin, Portsmouth Gaseous Diffusion Plant, POEF-TS-08, prepared for presentation at the Third International Uranium Hexafluoride Conference, Paducah, KY, (1995)

    TRUs, B, Si in Uranium Hexafluoride using UTEVA Resin, TRU Resin and ICP-AES, alpha-spec (GC195 )

    Download
  • Fern, M.J.; Thakkar, A.; Jassin, L.

    Recent Developments in the Analysis of Technetium-99, Journal of Nuclear and Radiochemical Sciences, Vol. 6, No. 3, pp. 223-225, (2005)

    Tc in using TEVA Resin and LSC (FM105 )

  • Egorov, Oleg; et al

    Analytical Chemistry, Vol. 70, No. 5, pp. 977-984, (1998)

    Tc in Nuclear Waste using TEVA Resin and LSC (EO198 )

    [ doi: 10.1021/ac971121t ]

  • Essling, A.M.; et al

    Determination of Uranium and Uranium Isotopes in High Silica Soils by Laser Kinetic Phosphorimetry and Thermal Ionization Mass Spectrometry, 37th Annual Conference on Bioassay, Analytical, and Environmental Radiochemistry, Ottawa, Canada, (1991)

    U in Soil using UTEVA Resin and TIMS (EA191 )

  • Chiarizia, R.; Gatrone, R.C.; Horwitz, E.P.

    Am(III) and Eu(III) Extraction by Aliquat·336 and Benzyl Substituted Quaternary Ammonium Sales from Nitrate and Thiocyanate Solutions, Solvent Extraction & Ion Exchange, Vol. 13, No. 4, pp. 615-645, (CR295), (1995)

    Am, Eu in Soil using TEVA Resin and alpha-spec (CR295 )

  • Hagan, M. 

    The Determination of Technetium-99 in Environmental Samples Using a Novel Separation Technique, 7th International Symposium On Radiochemical Analysis.  Bournemouth, UK, (1994)

    Tc in Milk, Marine using TEVA Resin and LSC (HM194 )

  • Harduin, J.C.; et al

    Analytical Determination of Actinides in Biological Samples, Radioprotection, Vol. 31, pp. 229-245, (1996)

    Actinides in Biological using TRU Resin, TEVA Resin and alpha-spec (HJ196 )

  • Carney, K.P.

    The Application of Micro-Column Solid Phase Extraction Techniques for the Determination of Rare Earth Elements in Actinide Containing Matrices, Journal of Radioanalytical & Nuclear Chemistry, Articles, Vol. 194, No. 1, pp. 41-49, (1995)

    Rare Earths in Actinides Containing Matrices using UTEVA Resin and ICP-AES (CK195 )

    [ doi: 10.1007/BF02037611 ]

  • Burnett, W.; Smith, Greg; Schultz, M.; Corbett, D.R.; Cable, P.; Walden, Ayanna; Stewart, B.; Selman, Jim

    Actinide Assay of Environmental Samples, presented at 43rd Conference on Bioassay, Analytical and Environmental Radiochemistry, (1997)

    Actinides in Soil using UTEVA Resin, TEVA Resin, TRU Resin and alpha-spec (BW297 )

  • Bunzl, K.; Kracke, W. 

    Efficient Radiochemical Separation for the Determination of Plutonium in Environmental Samples, Using a Supported, Highly Specific Extractant, Journal of Radioanalytical and Nuclear Chemistry, Letters., Vol. 186, No. 5, pp. 401-413, (1994)

    Pu in Soil using TEVA Resin and alpha-spec (BK194 )

    [ doi: 10.1007/BF02162624 ]

  • Butterworth, J.C.; Livens, F.R.; Makinson, P.R.

    Development of a Method for the Determination of Low Levels of Technetium-99, The Science of the Total Environment, Vol. 173/174, pp.293-300, (1995)

    Tc in Soil using TEVA Resin and ICP-MS, LSC (BJ195 )

    [ doi: 10.1016/0048-9697(95)04774-3   ]

  • Berne, Anna

    Americium Separation in Larger Soil Samples (up to 50g), 41st Annual Conference On Bioassay, Analytical & Environmental Radiochemistry (Eichrom Workshop). Boston, MA, (1995)

    Am in Soil using TRU Resin, TEVA Resin and alpha-spec (BE195 )

  • Beals, D.

    Determination of Technetium-99 in Aqueous Samples by Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry, 3rd International Conference On Nuclear and Radiochemistry., Vienna, Austria, (1992)

    Tc in Aqueous using TEVA Resin and ICP-MS (BD192 )

    Download
  • Beals, D.; et al

    Technetium-99, Iodine-129 and Tritium in the Waters of the Savannah River Site, The Science of the Total Environment, Vol. 173/174, pp. 101-115, (1995)

    Tc in Water using TEVA Resin and ICP-MS (BD195 )

    [ doi: 10.1016/0048-9697(95)04769-7   ]

  • Banavali, A.D.

    The Determination of Technetium-99 in Low-Level Radioactive Waste, Radioactivity & Radiochemistry, Vol. 6, No. 3, pp. 26-35, (1995)

    Tc in Low-Level Waste using TEVA Resin and LSC (BA195 )

  • Altzitzoglou, T.; et al

    Accurate Measurement of Low-level Radioactivity in Various Matrices, Eichrom Users’ Group Meeting, Karlsruhe, Germany, (1997)

    Pb, Actinides, Rn, Sr in Environmental, Bioassay using TRU Resin, UTEVA Resin and alpha-spec, LSC, GPC (AT197 )

  • Agarande, M.; et al

    Selected Aspects of Uranium Trace Analysis for Safeguards Purposes, 17th Annual ESARDA Conference. CEC, JRC, IRMM, (1994)

    U in Environmental using UTEVA Resin and ICP-MS (AM195 )

  • Adriens, Annemie G.; et al

    Determination of Uranium and Thorium Concentrations in Soils. Comparison of Isotope Dilution-Secondary Ion Mass Spectrometry and Isotope Dilution-Thermal Ionization Mass Spectrometry, Analytical Chemistry, Vol. 64, pp. 2945-2950, (1992)

    U, Th in Soil using UTEVA Resin and ID-TIMS, ID-SIMS (AA192 )

    [ doi: 10.1021/ac00047a012 ]

  • Maxwell, S.L.; Culligan, B.K.; Jones, V.D.; Nichols, S.T.; Bernard, M.A.; Noyes, G.W.

    Determination of 237Np and Pu isotopes in large soil samples by inductively coupled plasma mass spectrometry, Analytica Chimica Acta, Vol. 682, Issues 1-2, pp 130-136, (2010)

    Np, Pu in Soil using TEVA Resin, DGA Resin and ICP-MS, alpha-spec (MS410)

    [ doi: 10.1016/j.aca.2010.10.001 ]

  • McAlister, D.R.; Horwitz, E. P.

    Chromatographic generator systems for the actinides and natural decay series elements, Radiochimica Acta, Vol. 99, No. 3, pp. 151-159, (2011)

    Bi, Po, Pb, Ra, Ac, Th, Np in Medical Isotope Production using TEVA Resin, DGA Resin, UTEVA Resin, Sr Resin, Pre-Filter Resin, C8 Resin and alpha-spec, GPC, gamma-spec, LSC (MD111)

    [ doi: 10.1524/ract.2011.1804 ]

Interested in learning more about our products?

Send us a message via our contact form, and we'll answer any questions you may have.

Contact Us